 What is Flange? What are the Types of Flanges Used in Piping System ?

Flanges are essential components in piping systems, used to connect pipes, valves, pumps, and other equipment. They allow for easy assembly and disassembly, inspection, and maintenance. Here are the common types of flanges used:


1. Weld Neck Flange

- Application: High-pressure, high-temperature environments.

- Features: Long tapered hub, welded to the pipe.

 

2. Slip-On Flange

- Application: Low-pressure applications.

- Features: Slides over the pipe, welded on both the inside and outside.


3. Socket Weld Flange

- Application: Small-diameter, high-pressure pipes.

- Features: Socket inside the flange, pipe inserted and welded.


 4. Blind Flange

- Application: Closing the end of a piping system.

- Features: No bore, used to block off a pipeline or valve.


5. Threaded Flange

- Application: Low-pressure, low-temperature systems.

- Features: Internal threads, screwed onto the pipe.

6

. Lap Joint Flange

- Application: Pipes with frequent disassembly.

- Features: Two-piece assembly (flange and stub end), used with a stub end.


7. Reducing Flange

- Application: Connecting pipes of different sizes.

- Features: Bore designed to fit pipes of varying sizes.


8. Long Weld Neck Flange

- Application: High-pressure, high-temperature systems.

- Features: Extended neck, often used in equipment connections.


9. Orifice Flange

- Application: Measuring flow rates.

- Features: Used with orifice meters, has pressure taps for flow measurement.


10. Expander Flange

- Application: Increasing pipe size.

- Features: Combines a flange and a reducer.


11. Ring Type Joint (RTJ) Flange

- Application: High-pressure, high-temperature applications.

- Features: Metal ring inserted into the flange groove for sealing.


Each type of flange is selected based on factors like pressure and temperature requirements, pipe material, and installation and maintenance needs.

Comments

Popular posts from this blog

Type of Heat Exchanger

 There are several types of heat exchangers used in HVAC systems, including: 1. Coil Type:     - Chilled water coils     - Hot water coils     - DX (direct expansion) coils     - Evaporator coils     - Condenser coils 2. Shell and Tube Type:     - U-tube heat exchangers     - Straight tube heat exchangers 3. Plate Type:     - Plate and frame heat exchangers     - Plate and shell heat exchangers 4. Finned Tube Type:     - Finned tube heat exchangers 5. Spiral Type:     - Spiral heat exchangers 6. Regenerative Type:     - Regenerative heat exchangers 7. Adiabatic Type:     - Adiabatic wheel heat exchangers 8. Run-Around Coil Type:     - Run-around coil heat exchangers These heat exchangers are used in various applications, including: - Air conditioning - Heating - Ventilation - Refrigeration - Heat recovery - Industrial processes Each type of hea...

HVAC common unit converter chart

 Here's a comprehensive HVAC unit converter chart: Volume Flow Rate 1.CFM (Cubic Feet per Minute) to CMH (Cubic Meters per Hour):  1 CFM ≈ 1.699 CMH 2.CFM to m³/s (Cubic Meters per Second):  1 CFM ≈ 0.000472 m³/s Airflow Velocity 1.FPM (Feet per Minute) to m/s (Meters per Second):  1 FPM ≈ 0.00508 m/s 2.m/s to FPM:  1 m/s ≈ 196.85 FPM Energy and Power 1.BTU/h (British Thermal Units per Hour) to kW (Kilowatts):  1 BTU/h ≈ 0.000293 kW 2.Tons of Refrigeration to kW:  1 Ton ≈ 3.517 kW Pressure 1.Inches of Water Gauge (in wg) to Pascals (Pa):  1 in wg ≈ 249.08 Pa 2.PSI (Pounds per Square Inch) to kPa (Kilopascals):  1 PSI ≈ 6.895 kPa Temperature 1.°F (Fahrenheit) to °C (Celsius):  °C = (°F - 32) × 5/9 2.°C to °F:  °F = °C × 9/5 + 32 Additional Conversions Length 1.Inches to Millimeters:   1 inch = 25.4 mm 2.Feet to Meters:  1 foot = 0.3048 meters Area Square Feet to Square Meters:  1 sq ft = 0.0929 sq m Volume Gallons to L...

VALVES USED IN A CHILLER SYSTEM AND THE TYPICAL VALVE PACKAGE

  VALVES USED IN A CHILLER SYSTEM AND THE TYPICAL VALVE PACKAGE 1.Chilled Water Side Valves ⇒Isolation valve (manual/electric actuated). ⇒ Installed on CHW supply and return lines.  ⇒ Used to isolate chiller for maintenance. 2. Balancing Valve (Manual or Automatic)  ⇒ Ensures correct flow rate to/from chiller.  ⇒ Helps maintain Delta T and proper flow distribution.  ⇒ Located after evaporator outlet (return line). 3. Differential Pressure Bypass Valve (if 2-way valves in system)  ⇒ Prevents excess pressure build-up when terminals shut.  ⇒ Maintains flow through chiller. 4. Flow Switch  ⇒ Senses chilled water flow across evaporator.  ⇒ Safety interlock: trips chiller if flow is lost.  ⇒ Usually paddle type or electronic. 5. Air Vent Valve (Manual or Automatic)  ⇒ Removes air pockets.  ⇒ Placed at high points of piping and chiller headers. 6. Drain Valve  ⇒ For flushing, cleaning, and maintenance.  ⇒ Located at low poin...