HVAC common unit converter chart

Image
 Here's a comprehensive HVAC unit converter chart: Volume Flow Rate 1.CFM (Cubic Feet per Minute) to CMH (Cubic Meters per Hour):  1 CFM ≈ 1.699 CMH 2.CFM to m³/s (Cubic Meters per Second):  1 CFM ≈ 0.000472 m³/s Airflow Velocity 1.FPM (Feet per Minute) to m/s (Meters per Second):  1 FPM ≈ 0.00508 m/s 2.m/s to FPM:  1 m/s ≈ 196.85 FPM Energy and Power 1.BTU/h (British Thermal Units per Hour) to kW (Kilowatts):  1 BTU/h ≈ 0.000293 kW 2.Tons of Refrigeration to kW:  1 Ton ≈ 3.517 kW Pressure 1.Inches of Water Gauge (in wg) to Pascals (Pa):  1 in wg ≈ 249.08 Pa 2.PSI (Pounds per Square Inch) to kPa (Kilopascals):  1 PSI ≈ 6.895 kPa Temperature 1.°F (Fahrenheit) to °C (Celsius):  °C = (°F - 32) × 5/9 2.°C to °F:  °F = °C × 9/5 + 32 Additional Conversions Length 1.Inches to Millimeters:   1 inch = 25.4 mm 2.Feet to Meters:  1 foot = 0.3048 meters Area Square Feet to Square Meters:  1 sq ft = 0.0929 sq m Volume Gallons to L...

Filter size calculation for HVAC system

Image
Filter size calculation for HVAC system    To calculate the filter size for an HVAC system, you'll need to consider the following factors: 1. Airflow rate (CFM or m³/h) 2. Filter efficiency (e.g., MERV rating) 3. Filter type (e.g., pleated, cartridge, or HEPA) 4. System pressure drop (Pa or in. w.g.) 5. Filter housing dimensions (if existing) Here's a simplified calculation: 1. Determine the airflow rate (Q) in CFM or m³/h. 2. Choose a filter efficiency (E) based on the desired MERV rating. 3. Select a filter type and its corresponding pressure drop (∆P) at the desired airflow rate. 4. Calculate the required filter face area (A) using: A = Q / (E x ∆P) where A is the filter face area in square feet (ft²) or square meters (m²). 1. Consider the filter housing dimensions (if existing) and adjust the filter size accordingly. Some general guidelines for filter sizes are: - Residential:   12-24 inches (305-610 mm) wide, 12-36 inches (305-914 mm) deep - Commercial:  24-48 i...

Type of fasteners or bolts

  Here are some common types: 1.Screws:  Used for wood, metal, or drywall. 2.Bolts:  Used with nuts for heavy-duty applications. 3.Nuts:   Used with bolts for secure fastening. 4.Rivets:   Used for permanent fastening. 5. Anchors :  Used for wall or concrete fastening. Some specific types include: 1.Hex bolts 2.Socket head screws 3.Torx screws 4.Phillips head screws 5.Lag screws More information on specific types of fasteners. Here are some examples: 1.Hex Bolts Hex bolts are a type of bolt with a hexagonal head and threaded shaft. They're commonly used in construction, automotive, and industrial applications. 2.Socket Head Screws Socket head screws have a cylindrical head with a hexagonal recess. They're often used in precision applications, such as machinery and equipment. 3.Torx Screws Torx screws have a star-shaped recess and are commonly used in automotive, aerospace, and electronics applications. 4.Phillips Head Screws Phillips head screws have a cros...

Thermostats

Image
 Thermostats Thermostats are devices that: 1.Regulate temperature:   Control the temperature in a building or space. 2.Sense temperature changes:  Detect changes in temperature and send signals to HVAC equipment. 3.Maintain setpoints:  Keep the temperature at a set level, within a specified range. Types of thermostats: 1.Mechanical thermostats:  Use a physical mechanism to sense temperature changes. 2.Digital thermostats:   Use electronic sensors and displays to regulate temperature. 3.Smart thermostats:  Can learn occupancy schedules, adjust temperature, and be controlled remotely. 4.Programmable thermostats:  Allow for scheduling temperature changes. Key characteristics of thermostats: 1.Accuracy and reliability. 2.Sensitivity and response time. 3.Adjustability and programmability. 4.Compatibility with HVAC systems. 5.Energy efficiency and optimization. Factors affecting thermostat performance: 1.Proper installation and calibration. 2.Regular ma...

Plenums

Image
  Plenums Plenums are an essential component of HVAC systems, serving as: 1.Air distribution chambers: Connecting ductwork to HVAC equipment. 2.Pressure vessels:  Maintaining consistent air pressure throughout the system. Types of plenums: 1.Supply plenums:  Distribute conditioned air to zones or spaces. 2.Return plenums:  Collect air from zones or spaces for re-conditioning. 3.Neutral plenums:  Used for both supply and return air. Key characteristics of plenums: 1.Size and shape:  Varying sizes and shapes to fit different applications. 2.Material:  Typically made of sheet metal, fiberglass, or plastic. 3.Seals and connections:  Must be airtight to prevent leaks. 4.Access and maintenance:  Designed for easy access and maintenance. Factors affecting plenum performance: 1.Proper sizing and design. 2.Leakage and sealing. 3.Insulation and thermal performance. 4.Airflow and pressure. 5.Maintenance and cleaning. Maintenance tips: 1.Regularly inspec...

Coils (heating, cooling)

Image
Coils (heating, cooling)   Coils are a crucial component of HVAC systems, responsible for: 1.Heat transfer:  Exchanging heat between air and a fluid (water, refrigerant, or steam). 2.Heating and cooling:   Conditioning air through heat transfer. Types of coils: 1.Chilled water coils:  Use chilled water to cool air. 2.Hot water coils:  Use hot water to heat air. 3.DX (Direct Expansion) coils:  Use refrigerant to cool air. 4.Steam coils:   Use steam to heat air. 5.Electric coils:   Use electricity to heat air. Key characteristics of coils: 1.Material:  Typically made of copper, aluminum, or steel. 2.Configuration:  Can be circular, oval, or rectangular. 3.Size and capacity:   Varying sizes and capacities to fit different applications. 4.Fin spacing and design:   Affects heat transfer efficiency. Factors affecting coil performance: 1.Proper sizing and selection. 2.Regular maintenance and cleaning. 3.Fluid flow rates and temperatur...

Blowers

Image
Blowers Blowers are an essential component of HVAC systems, responsible for: 1.Air circulation:  Moving air through the system and building. 2.Pressure increase:  Boosting air pressure to overcome system resistance. 3.Air distribution:  Distributing conditioned air to various zones or spaces. Types of blowers: 1.Centrifugal blowers:  Use a spinning impeller to increase air pressure. 2.Axial blowers:  Use a spinning propeller to move air. 3.Cross-flow blowers:  Use a cylindrical impeller to move air. 4.Regenerative blowers:  Use a spinning impeller to increase air pressure. Key characteristics of blowers: 1.Flow rate:  Measured in CFM (cubic feet per minute). 2.Pressure rise:   Measured in inches of water gauge (in wg). 3.Efficiency:  Measured by fan efficiency grade (FEG) or fan motor efficiency. 4.Noise level:   Measured in decibels (dB). Factors affecting blower performance: 1.Proper sizing and selection. 2.Regular maintenance and...